Appliance · Kitchen

How many watts does a portable induction cooktop use — and what can run it?

A single-burner induction cooktop (Duxtop 9600LS) draws up to 1,800 W, with levels from 100 W. Which power stations and generators can run it.

Running draw1,800 W source
Starting drawnone
Average per hour of usenot published
Typical use1 h/day

Draw depends on the power level selected; 1800 W is the top setting.

The representative model is the Duxtop 9600LS, a single-burner portable induction cooktop. The Secura, the company behind Duxtop, lists it at 1,800 W, with 20 preset power levels from 100 W to 1,800 W. The 1,800 W is the top setting, so the tables show the most it can draw.

What changes the draw

The power level you select is the main variable: the cooktop is sold by its power levels, and a simmer setting asks for a fraction of the maximum. Boiling water or searing at the top setting is the case the station has to handle; holding a pot warm is much lighter.

No starting surge

This page has no starting figure, and the Champion wattage chart lists a portable induction cooktop among appliances that need no extra starting watts. The deciding number is continuous output at the setting you use: 1,800 W at the top, so stations rated 1,500 W continuous fail there.

Reading the tables

Runtime is time at the full 1,800 W. The page assumes one hour a day, 1,800 Wh. Example: the EcoFlow DELTA 3 record has no maker factor, so the default 0.85 applies: 1,024 Wh × 0.85 ÷ 1,800 W = 0.5 hours. At the 100 W level the same arithmetic gives 8.7 hours.

Power stations that can run it

Pass = continuous output ≥ 1800 W. Runtime = capacity × maker's factor ÷ 1800 W, nothing else plugged in. Method.

ModelFitsRuntime at 1800 WCapacityList price
MARBERO 88Wh Portable Power Station (M82)No—89 Wh$119.99
DARAN R100 (89.6Wh)No—90 Wh$149.99
Bluetti EB3ANo—269 Wh$219
EcoFlow RIVER 3 PlusNo—286 Wh$299
Anker SOLIX C300No—288 Wh$429.99
Anker SOLIX C300 DCNo—288 Wh$349.99
Jackery Explorer 300No—292 Wh$289
Goal Zero Yeti 500No—499 Wh$499.95
Bluetti AC70No—768 Wh$359
Anker SOLIX C1000 Gen 2Yes29 min1,024 Wh$499.99
EcoFlow DELTA 3Yes29 min1,024 Wh$699
EcoFlow DELTA 3 ClassicYes29 min1,024 Wh$599
EcoFlow DELTA 3 PlusYes29 min1,024 Wh$799
Anker SOLIX C1000XYes30 min1,056 Wh$469.99
Jackery Explorer 1000 v2No—1,070 Wh$559
Bluetti AC180Yes29 min1,152 Wh$499
Jackery Explorer 1000 PlusYes36 min1,264 Wh$699
Goal Zero Yeti 1500Yes43 min1,505 Wh$1,499.95
Goal Zero Yeti 1500XYes43 min1,516 Wh$1,124.89
EcoFlow DELTA Max (2000)Yes57 min2,016 Wh—
Jackery Explorer 2000 v2Yes58 min2,042 Wh$999
Jackery Explorer 2000 PlusYes58 min2,043 Wh—
Anker SOLIX C2000 Gen 2Yes58 min2,048 Wh$899.99
Bluetti AC200LYes58 min2,048 Wh$899
EcoFlow DELTA 2 MaxYes58 min2,048 Wh$1,299
EcoFlow DELTA 3 MaxYes58 min2,048 Wh$1,199
EcoFlow DELTA 3 Max PlusYes58 min2,048 Wh$1,599
Bluetti Elite 200 V2Yes53 min2,074 Wh$899
Jackery HomePower 3000Yes1.5 h3,072 Wh$1,499
Anker SOLIX F3800 PlusYes1.8 h3,840 Wh$2,599.99
EcoFlow DELTA Pro 3Yes1.9 h4,096 Wh$3,299

Generators that can run it

ModelFitsLoadPublished run timeCO sensorList price
Champion 100396 3400W Electric Start Dual Fuel InverterYes58 % (gasoline)7.5 h @ 25 %No—
Champion 201241 13,500W Electric Start Tri Fuel GeneratorYes13 % (gasoline)8 h @ 50 %Yes—
Champion 201319 4500W Electric Start Dual Fuel InverterYes51 % (gasoline)14 h @ 25 %Yes—
DuroMax XP13000EHYes17 % (gasoline)17 h @ 25 % · 8 h @ 50 %Yes$1,299
DuroMax XP9500iHYes24 % (gasoline)21 h @ 25 % · 11 h @ 50 %Yes$1,999
Generac GP8000E (with COsense, model 7715)Yes23 % (gasoline)10 h @ 50 %Yes—
Generac iQ3500 (with COsense)Yes60 % (gasoline)14.1 h @ 25 % · 8.9 h @ 50 %Yes—
Honda EU2200iYes100 % (gasoline)8.1 h @ 25 % · 3.2 h @ 100 %Yes$1,199
Honda EU3200iYes69 % (gasoline)8.6 h @ 25 % · 3.3 h @ 100 %Yes$2,799
Honda EU7000iSYes33 % (gasoline)16 h @ 25 % · 6.4 h @ 100 %Yes$4,899
WEN DF680iXYes35 % (gasoline)6.1 h @ 50 %Yes$803.40
WEN GN400iYes51 % (gasoline)7 h @ 50 %No$479.99
Westinghouse WGen7500DFcYes24 % (gasoline)11 h @ 25 %Yes$1,299
Westinghouse WGen9500DFYes19 % (gasoline)12 h @ 25 % · 8 h @ 50 %No$1,249
Westinghouse WGen9500DFcYes19 % (gasoline)12 h @ 25 % · 8 h @ 50 %Yes$1,399
Westinghouse WGen9500DFc EFIYes19 % (gasoline)15 h @ 25 % · 10 h @ 50 %Yes$1,549

Frequently asked questions

How many watts does a portable induction burner use?
The Duxtop 9600LS is rated 1,800 W at its top setting, with 20 power levels from 100 W to 1,800 W, per The Secura's product page (Duxtop's maker).
Can a power station run an induction cooktop?
At the full 1,800 W setting, only stations rated 1,800 W continuous or more pass. The EcoFlow DELTA 3 is rated exactly 1,800 W; the Jackery Explorer 1000 v2 (1,500 W) fails at that setting.
How long can a power station run an induction burner?
For the 1,024 Wh EcoFlow DELTA 3 at the default 0.85 factor: 1,024 × 0.85 ÷ 1,800 W = 0.5 hours at the top setting; at the 100 W level, 1,024 × 0.85 ÷ 100 = 8.7 hours.

Sources

  1. The Secura (Duxtop maker) — Duxtop 9600LS/BT-200DZ portable induction cooktop product page (accessed 2026-10-31)

Page updated 2026-10-31.