Appliance · Kitchen

How many watts does a French-door refrigerator use — and what can run it?

Frigidaire Gallery 28.8 cu ft French-door fridge: 396 W rated, 1,200 W to start, 74 W yearly average — which power stations and generators run it.

Running draw396 W source
Starting draw1,200 W source
Average per hour of use74 W source
Typical use24 h/day

Compressor cycles on and off; avg_w is the yearly average from the ENERGY STAR annual-energy figure.

The representative model is the Frigidaire Gallery GRFN2853AF (28.8 cu ft). Its specification sheet lists 3.3 amps at 120 volts — the 396 W running figure — and the ENERGY STAR record for the model gives 652 kWh a year, the source of the 74 W average. The amp figure is the appliance's electrical rating rather than the compressor's actual running draw, so the running-draw column below is the cautious one. Frigidaire publishes no starting figure; the 1,200 W is the top of the refrigerator row (800–1,200 W) on the Champion generator wattage chart.

What changes the draw

A larger cabinet and the built-in ice maker both add to the work the compressor does, which is why this model's yearly average is higher than the top-freezer example. Day to day, room temperature, door openings, the thermostat setting and restocking with warm food decide how long each compressor cycle lasts.

Why the starting draw matters

The compressor motor pulls a short burst well above its running draw each time it starts. A station must cover that burst plus everything else already running; one that cannot will trip its overload protection even though 396 W is well inside its continuous rating. The rule is on the methodology page.

Reading the tables

"Runtime at 396 W" is the floor — compressor on all the time. "At average draw" uses 74 W and reflects normal cycling. Example: the Jackery Explorer 2000 v2 record carries no maker factor, so the default 0.85 applies: 2,042 Wh × 0.85 ÷ 74 W = 23.5 hours.

Power stations that can run it

Pass = continuous output ≥ 396 W and peak output ≥ 1200 W. Runtime = capacity × maker's factor ÷ 396 W, nothing else plugged in. Method.

ModelFitsRuntime at 396 WAt average drawCapacityList price
MARBERO 88Wh Portable Power Station (M82)No——89 Wh$119.99
DARAN R100 (89.6Wh)No——90 Wh$149.99
Bluetti EB3AYes33 min2.9 h269 Wh$219
EcoFlow RIVER 3 PlusYes37 min3.3 h286 Wh$299
Anker SOLIX C300No——288 Wh$429.99
Anker SOLIX C300 DCNo——288 Wh$349.99
Jackery Explorer 300No——292 Wh$289
Goal Zero Yeti 500No——499 Wh$499.95
Bluetti AC70Yes1.6 h8.8 h768 Wh$359
Anker SOLIX C1000 Gen 2Yes2.2 h12 h1,024 Wh$499.99
EcoFlow DELTA 3Yes2.2 h12 h1,024 Wh$699
EcoFlow DELTA 3 ClassicYes2.2 h12 h1,024 Wh$599
EcoFlow DELTA 3 PlusYes2.2 h12 h1,024 Wh$799
Anker SOLIX C1000XUnclear — no peak figure——1,056 Wh$469.99
Jackery Explorer 1000 v2Yes2.3 h12 h1,070 Wh$559
Bluetti AC180Unclear — no peak figure——1,152 Wh$499
Jackery Explorer 1000 PlusYes2.7 h15 h1,264 Wh$699
Goal Zero Yeti 1500Yes3.2 h17 h1,505 Wh$1,499.95
Goal Zero Yeti 1500XYes3.3 h17 h1,516 Wh$1,124.89
EcoFlow DELTA Max (2000)Unclear — no peak figure——2,016 Wh—
Jackery Explorer 2000 v2Yes4.4 h23 h2,042 Wh$999
Jackery Explorer 2000 PlusYes4.4 h23 h2,043 Wh—
Anker SOLIX C2000 Gen 2Yes4.4 h24 h2,048 Wh$899.99
Bluetti AC200LYes4.4 h24 h2,048 Wh$899
EcoFlow DELTA 2 MaxYes4.4 h24 h2,048 Wh$1,299
EcoFlow DELTA 3 MaxYes4.4 h24 h2,048 Wh$1,199
EcoFlow DELTA 3 Max PlusYes4.4 h24 h2,048 Wh$1,599
Bluetti Elite 200 V2Unclear — no peak figure——2,074 Wh$899
Jackery HomePower 3000Yes6.6 h35 h3,072 Wh$1,499
Anker SOLIX F3800 PlusUnclear — no peak figure——3,840 Wh$2,599.99
EcoFlow DELTA Pro 3Yes8.8 h47 h4,096 Wh$3,299

Generators that can run it

ModelFitsLoadPublished run timeCO sensorList price
Champion 100396 3400W Electric Start Dual Fuel InverterYes13 % (gasoline)7.5 h @ 25 %No—
Champion 201241 13,500W Electric Start Tri Fuel GeneratorYes3 % (gasoline)8 h @ 50 %Yes—
Champion 201319 4500W Electric Start Dual Fuel InverterYes11 % (gasoline)14 h @ 25 %Yes—
DuroMax XP13000EHYes4 % (gasoline)17 h @ 25 % · 8 h @ 50 %Yes$1,299
DuroMax XP9500iHYes5 % (gasoline)21 h @ 25 % · 11 h @ 50 %Yes$1,999
Generac GP8000E (with COsense, model 7715)Yes5 % (gasoline)10 h @ 50 %Yes—
Generac iQ3500 (with COsense)Yes13 % (gasoline)14.1 h @ 25 % · 8.9 h @ 50 %Yes—
Honda EU2200iYes22 % (gasoline)8.1 h @ 25 % · 3.2 h @ 100 %Yes$1,199
Honda EU3200iYes15 % (gasoline)8.6 h @ 25 % · 3.3 h @ 100 %Yes$2,799
Honda EU7000iSYes7 % (gasoline)16 h @ 25 % · 6.4 h @ 100 %Yes$4,899
WEN DF680iXYes8 % (gasoline)6.1 h @ 50 %Yes$803.40
WEN GN400iYes11 % (gasoline)7 h @ 50 %No$479.99
Westinghouse WGen7500DFcYes5 % (gasoline)11 h @ 25 %Yes$1,299
Westinghouse WGen9500DFYes4 % (gasoline)12 h @ 25 % · 8 h @ 50 %No$1,249
Westinghouse WGen9500DFcYes4 % (gasoline)12 h @ 25 % · 8 h @ 50 %Yes$1,399
Westinghouse WGen9500DFc EFIYes4 % (gasoline)15 h @ 25 % · 10 h @ 50 %Yes$1,549

Frequently asked questions

How many watts does a French-door refrigerator use?
For the Frigidaire Gallery GRFN2853AF: 396 W running (3.3 A × 120 V from the spec sheet), about 1,200 W at compressor start (top of the Champion chart range), and 74 W averaged over a year (652 kWh ÷ 8,760 h, per ENERGY STAR).
Does a French-door fridge use more power than a top-freezer?
In this site's two examples, yes: 74 W average for the 28.8 cu ft French-door model against 47 W for the 18.3 cu ft top-freezer model. Both use the same 1,200 W starting figure.
How long will a 2,000 Wh power station run a French-door fridge?
For the 2,042 Wh Jackery Explorer 2000 v2 at the default 0.85 factor: 2,042 × 0.85 ÷ 74 W = 23.5 hours at the yearly average; 4.4 hours if the compressor ran nonstop at 396 W.
Why does a power station need 1,200 W peak for a fridge that runs at 396 W?
The compressor motor draws far more for an instant when it starts. A station whose peak output is below the starting figure can shut down at that moment even though its continuous rating is high enough. See how the fit is decided.

Sources

  1. Frigidaire — GRFN2853AF 28.8 cu ft French Door Refrigerator specification sheet (version 08/22), hosted by Canadian Appliance Source: Amps @ 120 Volts, Annual Energy (accessed 2026-10-31)
  2. ENERGY STAR Certified Residential Refrigerators dataset (data.energystar.gov) — Frigidaire GRFN2853A*, annual kWh (accessed 2026-10-31)
  3. Champion Power Equipment — Generator Wattage Chart (generator maker's chart, not the appliance maker) (accessed 2026-10-31)

Page updated 2026-10-31.