Appliance · Rv

How many watts does a 13,500 BTU RV air conditioner use — and what can run it?

A 13,500 BTU RV rooftop AC (Coleman-Mach 10): 1,625 W running in desert heat, 7,560 W locked-rotor start. Which power stations and generators can start it.

Running draw1,625 W source
Starting draw7,560 W source
Average per hour of usenot published
Typical use8 h/day

Representative model: Coleman-Mach 10, 452X3*8XX. Cooling full-load amps 13.2–13.6 A (compressor 11.0 A + fan 2.2–2.6 A) at A.R.I. standard condition.

The representative model is the Coleman-Mach 10 (452X3*8XX) rooftop unit from Airxcel. Its data sheet gives two running figures for cooling: 1,350 W at the A.R.I. standard condition (95 °F outdoor) and 1,625 W at the desert condition (120 °F outdoor). The site uses 1,625 W; the sheet, while saying Airxcel does not size generators itself, lists the desert-test figure as the one to account for when sizing one. The starting figure is the compressor's locked-rotor current, 63.0 A, times 120 V: 7,560 W.

What changes the draw

Airxcel's two figures show that outdoor heat raises the running draw. Sun on the roof, the thermostat setting and how well the RV holds its cool decide how often the compressor cycles. No daily average is published, so the tables use 1,625 W throughout; at the page's 8 hours a day that is 13,000 Wh.

Why the starting draw decides everything

Locked-rotor current is what the compressor draws before it turns — the upper limit of a start, which lasts a fraction of a second. Generic charts are far lower: the Champion chart lists 2,800–3,500 W starting for a 13,500 BTU RV unit. Using the maker's figure, though, almost every power station on this site fails, and so do generators below 7,560 W starting (fit rule). Stations whose maker publishes no peak figure are marked "Unclear": the start cannot be checked.

Reading the tables

Runtime assumes the compressor never cycles off. Example: the EcoFlow DELTA Pro 3 record has no maker factor, so the default 0.85 applies: 4,096 Wh × 0.85 ÷ 1,625 W = 2.1 hours.

Power stations that can run it

Pass = continuous output ≥ 1625 W and peak output ≥ 7560 W. Runtime = capacity × maker's factor ÷ 1625 W, nothing else plugged in. Method.

ModelFitsRuntime at 1625 WCapacityList price
MARBERO 88Wh Portable Power Station (M82)No—89 Wh$119.99
DARAN R100 (89.6Wh)No—90 Wh$149.99
Bluetti EB3ANo—269 Wh$219
EcoFlow RIVER 3 PlusNo—286 Wh$299
Anker SOLIX C300No—288 Wh$429.99
Anker SOLIX C300 DCNo—288 Wh$349.99
Jackery Explorer 300No—292 Wh$289
Goal Zero Yeti 500No—499 Wh$499.95
Bluetti AC70No—768 Wh$359
Anker SOLIX C1000 Gen 2No—1,024 Wh$499.99
EcoFlow DELTA 3No—1,024 Wh$699
EcoFlow DELTA 3 ClassicNo—1,024 Wh$599
EcoFlow DELTA 3 PlusNo—1,024 Wh$799
Anker SOLIX C1000XUnclear — no peak figure—1,056 Wh$469.99
Jackery Explorer 1000 v2No—1,070 Wh$559
Bluetti AC180Unclear — no peak figure—1,152 Wh$499
Jackery Explorer 1000 PlusNo—1,264 Wh$699
Goal Zero Yeti 1500No—1,505 Wh$1,499.95
Goal Zero Yeti 1500XNo—1,516 Wh$1,124.89
EcoFlow DELTA Max (2000)Unclear — no peak figure—2,016 Wh—
Jackery Explorer 2000 v2No—2,042 Wh$999
Jackery Explorer 2000 PlusNo—2,043 Wh—
Anker SOLIX C2000 Gen 2No—2,048 Wh$899.99
Bluetti AC200LNo—2,048 Wh$899
EcoFlow DELTA 2 MaxNo—2,048 Wh$1,299
EcoFlow DELTA 3 MaxNo—2,048 Wh$1,199
EcoFlow DELTA 3 Max PlusNo—2,048 Wh$1,599
Bluetti Elite 200 V2Unclear — no peak figure—2,074 Wh$899
Jackery HomePower 3000No—3,072 Wh$1,499
Anker SOLIX F3800 PlusUnclear — no peak figure—3,840 Wh$2,599.99
EcoFlow DELTA Pro 3Yes2.1 h4,096 Wh$3,299

Generators that can run it

ModelFitsLoadPublished run timeCO sensorList price
Champion 100396 3400W Electric Start Dual Fuel InverterNo52 % (gasoline)7.5 h @ 25 %No—
Champion 201241 13,500W Electric Start Tri Fuel GeneratorYes12 % (gasoline)8 h @ 50 %Yes—
Champion 201319 4500W Electric Start Dual Fuel InverterNo46 % (gasoline)14 h @ 25 %Yes—
DuroMax XP13000EHYes15 % (gasoline)17 h @ 25 % · 8 h @ 50 %Yes$1,299
DuroMax XP9500iHYes21 % (gasoline)21 h @ 25 % · 11 h @ 50 %Yes$1,999
Generac GP8000E (with COsense, model 7715)Yes20 % (gasoline)10 h @ 50 %Yes—
Generac iQ3500 (with COsense)No54 % (gasoline)14.1 h @ 25 % · 8.9 h @ 50 %Yes—
Honda EU2200iNo90 % (gasoline)8.1 h @ 25 % · 3.2 h @ 100 %Yes$1,199
Honda EU3200iNo63 % (gasoline)8.6 h @ 25 % · 3.3 h @ 100 %Yes$2,799
Honda EU7000iSNo30 % (gasoline)16 h @ 25 % · 6.4 h @ 100 %Yes$4,899
WEN DF680iXNo32 % (gasoline)6.1 h @ 50 %Yes$803.40
WEN GN400iNo46 % (gasoline)7 h @ 50 %No$479.99
Westinghouse WGen7500DFcYes22 % (gasoline)11 h @ 25 %Yes$1,299
Westinghouse WGen9500DFYes17 % (gasoline)12 h @ 25 % · 8 h @ 50 %No$1,249
Westinghouse WGen9500DFcYes17 % (gasoline)12 h @ 25 % · 8 h @ 50 %Yes$1,399
Westinghouse WGen9500DFc EFIYes17 % (gasoline)15 h @ 25 % · 10 h @ 50 %Yes$1,549

Frequently asked questions

How many watts does a 13,500 BTU RV air conditioner use?
Airxcel's data sheet for the Coleman-Mach 10 lists 1,350 W running at the A.R.I. standard condition (95 °F outdoor) and 1,625 W at the desert condition (120 °F outdoor). This page uses 1,625 W: the sheet says Airxcel does not size generators itself, but lists the desert-test running watts among the loads to account for when sizing one.
How many starting watts does an RV air conditioner need?
The sheet gives a compressor locked-rotor current of 63.0 A, which the site turns into 7,560 W (× 120 V) — the ceiling of a start. The Champion generator chart lists a much lower generic range, 2,800–3,500 W, for a 13,500 BTU RV unit.
Can a portable power station run an RV air conditioner?
With the 7,560 W starting figure, few can. The EcoFlow DELTA Pro 3 (4,000 W continuous, 8,000 W peak) passes and lasts 4,096 × 0.85 ÷ 1,625 = 2.1 hours; the Jackery HomePower 3000 fails on its 7,200 W peak.
Can a Honda EU7000iS run a 13,500 BTU RV AC?
Not by this page's figures: the Honda EU7000iS lists 7,000 W max, below 7,560 W. The Westinghouse WGen7500DFc (9,500 W starting on gasoline) passes.

Sources

  1. Airxcel — Coleman-Mach Mach 10 (452X3*8XX) data inquiry sheet (PDF hosted by retailer CamperID) (accessed 2026-10-31)